1 MW PV input
String Voc target ≤1,000 V at −5°C, with dedicated MPPT DC/DC and conversion headroom.
1,500 V DC-CLASS, DC-COUPLED TECHNOLOGY
A scalable, off-grid-capable, 1,500 V DC-class system with dedicated PV MPPT, bidirectional battery DC/DC and an optional separate AC input cabinet.
String Voc target ≤1,000 V at −5°C, with dedicated MPPT DC/DC and conversion headroom.
Up to 0.5C ramped output, governed by BMS, SOC, temperature and system limits.
Available site power is dynamically allocated across an even number of charging dispensers.
Grid, wind or diesel feed a separate transformer and AC/DC cabinet through a reserved 300 kW DC interface.
ENGINEERING BOUNDARY
At 0.5C, 2.5 MWh corresponds to approximately 1.25 MW theoretical battery output and 5 MWh to approximately 2.5 MW, before SOC, temperature and system derating.
EMS available power is the minimum of BMS, 0.5C, busbar, cable, protection, thermal and charging-equipment limits. BIDC quantity is calculated from minimum battery voltage, the 100 A module limit, derating, N+1 redundancy and fault exit.